Loading 3D model… large boards can take a moment.
Reconstructing the Analyzer’s RF Sweep from Its Local Oscillator A modular, analyzer‑synchronous architecture
The HP 8562A/B spectrum analyzer does not include a tracking generator.
However, it exposes enough of its internal LO system to build one externally.
This project implements a modular, sweep‑synchronous Tracking Generator (TG) that behaves as if it were a native part of the HP 8562A/B.
It reconstructs the analyzer’s RF sweep using only:
The TG becomes a slave to the analyzer’s LO system and rebuilds the RF sweep in real time across multiple microwave bands.
The HP 8562A/B is a legendary instrument: fast, sensitive, and extremely stable.
But without a tracking generator, it cannot perform:
This project fills that gap with a TG that follows the analyzer sweep exactly, using the analyzer’s own LO architecture.
The HP 8562A/B does not sweep an RF source.
It sweeps its first local oscillator and mixes incoming signals down to a fixed IF.
To cover 1 kHz–26 GHz, it uses automatic harmonic mixing, where each RF band uses a different harmonic of the LO:
| RF Band | Harmonic n | IF | LO Formula |
|---|---|---|---|
| 1 kHz–2.9 GHz | 1 | 3.9107 GHz | LO_SA = RF_SA + 3.9107 GHz |
| 2.75–6.46 GHz | 1 | 310.7 MHz | LO_SA = RF_SA + 0.3107 GHz |
| 5.86–13.0 GHz | 2 | 310.7 MHz | LO_SA = (RF_SA + 0.3107 GHz) / 2 |
| 12.4–19.7 GHz | 3 | 310.7 MHz | LO_SA = (RF_SA + 0.3107 GHz) / 3 |
| 19.1–26.0 GHz | 4 | 310.7 MHz | LO_SA = (RF_SA + 0.3107 GHz) / 4 |
For each band, the analyzer follows: n * LO_SA = RF_SA + IF
Because n changes with band, the analyzer LO becomes non‑linear with respect to the displayed frequency.
A tracking generator must compensate for this non‑linearity to stay aligned.
The TG uses the analyzer LO_SA (or a harmonic of it) as the primary LO and subtracts a fixed IF to recreate the analyzer’s RF:
RF_TG = (n * LO_SA) – IF_TG
Where:
This yields:
Base‑Band (n = 1):
RF_TG = LO_SA – 3.9107 GHz
6 cm (n = 1):
RF_TG = LO_SA – 0.3107 GHz
3 cm (n = 2):
RF_TG = (2 × LO_SA) – 0.3107 GHz
12 mm (n = 4, concept):
RF_TG = (4 × LO_SA) – 0.3107 GHz
This architecture reqires no swept PLLs in the microwave TG modules.
Sweep coherence comes entirely from the analyzer LO.
The TG system is composed of modular RF boards:
MCU board:
Reads sweep voltage, computes RF_SA for calibration, programs PLLs
RF SA‑LO Distribution board:
Conditions and splits the analyzer’s 1st LO to all TG modules
Base‑Band TG module:
0–2.9 GHz (uses MAX2870)
6 cm TG module:
4.4–6.4 GHz (LO_SA direct, IF_TG = 310.7 MHz)
3 cm TG module:
9.5–11.5 GHz (LO_SA ×2, IF_TG = 310.7 MHz)
12 mm TG module (concept):
22–26 GHz (LO_SA ×4, IF_TG = 310.7 MHz)
Conceptually:
Analyzer → LO Distribution → TG Modules → RF Outputs
Analyzer → 10 MHz → PLLs
Analyzer → V_sweep → MCU → Harmonic modules
Each TG module reconstructs the analyzer RF at its own band using a mixer‑based architecture.
Implemented TG bands:
Conceptual / future TG bands:
Analyzer coverage:
/docs/architecture
01-tg-system-architecture.md
02-lo-architecture.md
03-analyser-lo-internals.md
04-rf-sa-lo-distribution.md
05-baseband-module.md
06-6cm-module.md
07-3cm-module.md
08-12mm-module.md
/docs/architecture/images
architecture diagrams
/firmware
MCU firmware (Raspberry Pi Pico)
overview
images
/hardware/<module>
schematics, layouts, BOMs, images
/mechanical
enclosures, front panels
/usage
calibration and measurement tools
Checkout the discussion section for updates on the first results I have.
MIT License.
See LICENSE for details.
No comments yet. Be the first to ask about this board.