cognicity-floodsensor
PublicLoading…
cognicity-floodsensor
IoT water depth, temperature and humidity sensor code
Installation
First clone this repository and install dependencies:
git clone https://github.com/smart-facility/cognicity-floodsensor
cd cognicity-floodsensor
Database Schema
Schema is design for PostgreSQL with the PostGIS extension.
Create the schema by running schema/cognicity_floodsensor_pg_schema.sql in target database.
Lambda side
cd lambda
npm install
Copy lambda/sample_config.js to a file called config in the lambda subdirectory, and edit it to replace the sample PostgreSQL config string with your actual string.
Then in the lambda subdirectory
npm install
zip -r -9 ../lambda.zip *
and upload the lambda.zip file to AWS lambda.
Device-side
cd device
npm install
Set up a device and associated certificate in AWS IoT (CLI or console) and then copy the private key (as private.pem.key) and certificate (as certificate.pem.crt) under awsCerts/.
Set the configuration options as described in device/config.js
Run this (note it needs to be run as root to access the GPIO memory):
sudo node device.js
Ctrl-C to quit.
Units
All distances are stored as centimetres (cm), temperature in °C, and humidity as %.
Circuit
The circuit schematic we use with this software (included hard-coded pin numbers in set up of DHT and HC-SR04 libraries) is as follows:
No comments yet. Be the first to ask about this board.