100%
gas_nordic ads1299 view
Description

Imported from GitHub: bradkim06/gas_nordic · commit 3c07391 · license Apache-2.0

Description

gas sensing iot device(nrf52832)

README

Industrial Gas Monitor Firmware (nRF52832 + Zephyr)

Firmware version 1.0.2 for HHS's portable industrial gas monitor. The application runs on a custom nRF52832 board, measures multiple gases, and transmits real-time readings over Bluetooth® Low Energy. Environmental data is fused with the Bosch BSEC2 library to provide indoor air-quality indicators in addition to electrochemical gas concentrations.


Table of contents

  1. Key features
  2. Hardware overview
  3. Supported measurements
  4. Firmware architecture
  5. Build and flash
  6. Bluetooth protocol
  7. Calibration & persistent settings
  8. Reference tables
  9. License

Key features

  • Multi-gas sensing – Electrochemical front-end for oxygen and a selectable toxic gas channel (NO₂, CO, H₂S, Cl₂, NH₃, etc.) with temperature compensation and dynamic calibration algorithms.【F:src/gas.c†L1-L212】
  • Environmental monitoring – Integrated BME68x support with Bosch BSEC2 fusion to derive temperature, humidity, pressure, IAQ, equivalent CO₂, and VOC indices. BSEC state is saved to flash for consistent long-term behavior. 【F:drivers/bme68x_iaq/bme68x_iaq.c†L40-L460】【F:src/settings.c†L1-L137】
  • Bluetooth LE connectivity – Custom 128-bit GATT service publishes semicolon-delimited measurements every 10 seconds and accepts configuration commands from a companion application.【F:src/bluetooth.h†L5-L45】【F:src/bluetooth.c†L520-L585】
  • Robust low-power platform – Built on Zephyr RTOS (nRF Connect SDK v2.4.2) with watchdog, power management, persistent storage, and board-specific optimizations.【F:prj.conf†L1-L110】

Hardware overview

  • Target SoC: Nordic Semiconductor nRF52832 (ARM® Cortex®-M4F, BLE 5).
  • Custom board definition: boards/arm/hhs_nrf52832 (schematic and layout included in doc/).【F:boards/arm/hhs_nrf52832/hhs_nrf52832.yaml†L1-L53】
  • Latest hardware pack: doc/gas_nrf52832_rev1.0.1.pdf with matching schematic doc/gas_nrf52832_sch_rev0.1.0.pdf.
  • Peripheral highlights:
    • Bosch BME688/BME680 environmental sensor on I²C.
    • Dual-channel electrochemical sensor front-end via SAADC.
    • Battery gauge through voltage divider + ADC.
    • RGB status LED and watchdog support.

Supported measurements

DomainReported values
Electrochemical gasOxygen concentration (%VOL) and one selectable toxic gas in
ppm, both temperature compensated and filtered.【F:src/gas.c†L1-L212】
EnvironmentalTemperature (°C), relative humidity (%RH), barometric
pressure (Pa), IAQ score, equivalent CO₂ (ppm), and breath
VOC index via BSEC2.【F:drivers/bme68x_iaq/bme68x_iaq.c†L40-L460】
PowerBattery percentage derived from loaded voltage profile.
BLE telemetryTimestamped payload streamed every 10 seconds (default).

Firmware architecture

The firmware is organized into cooperative Zephyr threads and kernel events. A high-level flow is shown below:

---
title: Portable Gas Monitor Firmware Flow
---
stateDiagram-v2
    direction TB
    [*] --> ZephyrRTOS
    ZephyrRTOS --> BME68x_BSEC
    ZephyrRTOS --> Electrochemical_ADC
    ZephyrRTOS --> BluetoothLE

    state ZephyrRTOS {
        state BME68x_BSEC {
            direction LR
            initBSEC --> readEnvironmental : 3 s
            initBSEC --> computeIAQ : 60 s
        }
        state Electrochemical_ADC {
            direction TB
            sampleADC --> tempCompensation
            tempCompensation --> gasConversion
            gasConversion --> dynamicCalibration
        }
        state BluetoothLE {
            direction LR
            initialize --> advertise
            advertise --> connected
            connected --> notifyData : 10 s
        }
    }

Key modules reside in src/ (application logic), drivers/bme68x_iaq/ (BSEC2 integration), and lib/ (Bosch libraries). Threads communicate via Zephyr events for deterministic BLE publishing and alarm handling.

Build and flash

  1. Install prerequisites
    • nRF Connect SDK v2.4.2 with the Zephyr toolchain, west, and SEGGER J-Link tools.
    • Bosch BSEC2 library files are already provided under lib/.
  2. Fetch the source
    git clone https://github.com/<your-org>/gas_nordic.git
    cd gas_nordic
    west init -l .
    west update
    
  3. Build
    west build -b hhs_nrf52832 .
    
    The output image is generated at build/zephyr/zephyr.hex.
  4. Flash
    west flash
    
    or, to use Nordic's command-line tools directly:
    ./flash.sh
    
    (flash.sh performs a chip erase and programs the generated HEX via nrfjprog).【F:flash.sh†L1-L5】

Bluetooth protocol

The device exposes a proprietary 128-bit primary service (0000FFF0-0000-1000-8000-00805F9B34FB).【F:src/bluetooth.h†L9-L26】

CharacteristicUUIDPropertiesDescription
Measurement0000FFF1-0000-1000-8000-00805F9B34FBNotifyPeriodic payload O2;Gas;Battery;Temp;Pressure;Humidity separated by semicolons, integers scaled as <val1>.<val2> where applicable.【F:src/bluetooth.c†L536-L576】
Command0000FFF2-0000-1000-8000-00805F9B34FBWriteASCII commands for calibration and configuration: O2=<percent>, NO2=<ppm>, BT=<name>.【F:src/bluetooth.c†L60-L124】

Notifications are issued when a connection is active and the client enables CCCD. Each update corresponds to the latest sensor snapshot and is throttled to the configured 10 s publishing interval.

Calibration & persistent settings

  • Dynamic calibration continuously refines oxygen and toxic gas baselines by monitoring derivative stability, expected ranges, and board temperature. Manual calibration can be triggered by writing to the command characteristic as described above.【F:src/gas.c†L1-L212】【F:src/bluetooth.c†L60-L124】
  • Persistent storage uses Zephyr's settings/NVS subsystem to retain BSEC state, sensor calibration voltages, and the advertised Bluetooth name across reboots.【F:src/settings.c†L1-L200】
  • Battery reporting samples SAADC channels and converts them into a percentage using empirically tuned thresholds (see src/battery.c).

Reference tables

Oxygen concentration guide

CategoryConcentration rangeNotes
High oxygen> 24 %Elevated combustion risk.
Normal air20.9 %Nominal breathable atmosphere.
Elevated exposure risk19.5 – 20.9 %Monitor for dilution hazards.
Low oxygen16 – 19.5 %Impaired cognition and physical performance.
Anoxic< 16 %Life-threatening within minutes.

Indoor air quality (IAQ) interpretation

IAQ indexAir qualitySuggested action
0 – 50ExcellentNone required.
51 – 100GoodNone required.
101 – 150Lightly pollutedVentilate if convenient.
151 – 200Moderately pollutedIncrease ventilation with clean air.
201 – 250Heavily pollutedIdentify contamination source, improve airflow.
251 – 350Severely pollutedRestrict access, maximize ventilation.
> 351Extremely pollutedAvoid occupancy until levels normalize.

CO₂ comfort levels

LevelDescriptionppm
😆Healthy outdoor reference350
😀Healthy indoor climate600
🙂Acceptable indoors800
🙁Ventilation desirable1000
😩Ventilation necessary1200
😡Noticeable health effects2000
⚠️Dangerous for prolonged exposure5000

VOC hygiene guidance

RatingRecommendationExposure durationTVOC (ppm)
ExcellentTarget valueUnlimited0 – 0.065
GoodVentilation recommendedUnlimited0.065 – 0.22
ModerateIncrease ventilation, inspect for sources< 12 months0.22 – 0.66
PoorIntensify ventilation, locate emission sources< 1 month0.66 – 2.2
UnhealthyImmediate ventilation requiredHours2.2 – 5.5

License

Distributed under the terms of the MIT License. Bosch BSEC2 library usage is subject to its proprietary license (see lib/Bosch-BSEC2-Library).