Imported from GitHub: doppelhub/Honda_Insight_LiBCM · commit 16e12d8 · license CC-BY-SA-4.0
Description
Replacement BCM for G1 Honda Insight Lithium Conversion
README
Starting condition: Single 5AhG3 cell charged to 4.2 volts at 5.5 amps.
Test: Cell continuously discharged at 0.319 amps (C/15.7) down to 2.8 volts. Cell voltage measured every second (the test data).
The results from this data are used to calculate SoC from resting Voc.
Note: The raw data has several "0.00" volt readings, which occur when the received checksum doesn't match. This data can be discarded. There are way more data points than are required to draw useful conclusions.
I should rewrite the code to make it prevent writing errant data... but I'm not going to do that now. Any non-zero value is accurate.