FSAE

Hardware projects for the FSAE Electric 2019/2020 competition (Australia). 💻Github https://github.com/michaelruppe/FSAE

Resources

Team mentoring and design reviews available - contact through michaelruppe.com

ShutdownCircuit.com is a free resource to help new FSAE EV teams shortcut the growing pains of designing EV safety systems.

TSAL

A light that indicates presence of dangerous voltage within the Tractive System

The third iteration of the TSAL driver.

Watch a video walkthrough explaining the circuit operation and design decision.

Precharge

A device to precharge the Tractive System. This prototype features voltage feedback to protect AIRs. In open-loop systems, if a wiring fault develops - eg. precharge resistor is disconnected - then the precharge is ineffective and AIRs may become damaged.

The prototype Precharge module

HFL (Hard Fault Latch)

Latches momentary faults that are required to shutdown the EV.

Comments