Current-Probe

Public

@qeteshpony

Download board files

Files for version 1. Pick what you came for.

Share Current-Probe

Check access before sharing the link.

Who can open this board

Anyone can open this board. No sign-in is required.

This link opens the latest version. Copying it does not grant additional access.

Loading…

README

Current-Probe

CI

Hardware Documentation

A simple board to turn any oscilloscope into a current meter by running the load through the 4mm Terminals and connecting your oscilloscope to the BNC terminal.

The resistor footprint takes a 2512 SMD resistor which usually come with a rating of 1 to 3, sometimes 5 watts which is enough to run several amps through this board.

The connector footprints are made for the Altech/Hirschmann PB 4 4mm test jacks that take a standard 4mm test lead.

The BNC connector footprint is for the Amphenol B6252HB but there's lots of cheap, compatible connectors with the same footprint available

You can also use the M3 screw holes to connect to this board since they are wired in parallel to the connectors closest to each.